3rd Quarter Summative Test for EIM 10 SY 2021-2022
Quiz by Henry Gallardo Jr.
Feel free to use or edit a copy
includes Teacher and Student dashboards
Measure skillsfrom any curriculum
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
- edit the questions
- save a copy for later
- start a class game
- automatically assign follow-up activities based on students’ scores
- assign as homework
- share a link with colleagues
- print as a bubble sheet
- Q1
It a type of control panel that considered as the most reliable and cost-efficient.
Universal Control Panel
Synchronous Control Panel
Conventional Control Panel
Addressable Control Panel
30s - Q2
What does PD No. 1185 known for?
Building Regulation Code
Occupational Health and Safety Standards
Fire Code of the Philippines
30s - Q3
In Addressable Control Panel, fire detection is much faster because the components are connected in a single loop.
truefalseTrue or False30s - Q4
Categorize the different examples of devices into its type of components.
Users sort answers between categoriesSorting30s - Q5
It receives signals from alarm-initiating devices, processes the signals, and produce output signals that activates the notification appliances.
Users re-arrange answers into correct orderJumble30s - Q6
Pull station is an example of automatic initiating device.
falsetrueTrue or False30s - Q7
It is the most common category of notification appliance used because it can notify the occupants in a fast manner.
Audible
Textual
Tactile
Visual
30s - Q8
What is shown in the picture below?
Call Point
EOL Resistor
Detector
Battery
30s - Q9
Don't make battery connections until the installation is completed. The fuse of the batteries may be broken if the polarity is connected incorrectly.
truefalseTrue or False30s - Q10
Using end of line resistor, connect all manual call points and detectors and put a 4.7kΩ resistor at the start of the loop
falsetrueTrue or False30s - Q11
Where do we put all the connections of the components of fire alarm system?
30s - Q12
Which is TRUE on connecting the components of a Fire Alarm System?
Always determine the correct polarity of the components.
The resistors are connected at the start of the loop.
Connect first the power supply before the other components.
Keep in mind that all fire alarm control panels are the same with one another.
30s - Q13
The diagram below shows the correct connection of the components.
falsetrueTrue or False30s - Q14
It captures light and convert it into a video signal.
Users re-arrange answers into correct orderJumble30s - Q15
It's a component of CCTV system wherein the video footages are stored.
Monitor
DVR
Switchers
Camera
30s