ACS Revision

Quiz by Alan Moth

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
19 questions
Show answers
  • Q1
    If an uncontrolled gas escape is encountered, the first thing to do is...
    leave the site and inform the occupier as soon as possible
    notify CORGI
    apply the Gas Industry Unsafe Situations Procedure for At Risk installations
    inform the gas supplier or transporter
    30s
  • Q2
    Where should the procedure to be carried out in the event of a gas escape be found?
    Affixed to the service pipe riser
    On or near to the appliance
    Affixed to the emergency control
    Affixed to the meter
    30s
  • Q3
    The main constituents of complete combustion are...
    water vapour and carbon dioxide
    carbon monoxide and nitrogen
    methane and water vapour
    nitrogen and methane
    30s
  • Q4
    The main visual sign of incomplete combustion within an appliance is...
    stable blue flames with well-defined inner and outer cones
    limescale deposits on the heat exchanger
    soot formation, changes in the flame picture or flame impingement
    carbon dioxide pluming from the burner
    30s
  • Q5
    The reason for waiting one minute before timing the soundness test is to...
    allow the regulator to settle
    allow for temperature stabilisation
    reduce the gas velocity
    prevent the ingress of air
    30s
  • Q6
    Providing there is no smell of gas, on an existing installation with appliances connected, the allowable pressure drop with an E6 meter fitted is....
    2mb
    8mb
    4mb
    0mb
    30s
  • Q7
    On an existing installation with no appliances fitted, the allowable pressure drop is...
    related to the total volume of the meter and pipework
    calculated by adding the total volume of the meter, pipework and appliances
    determined by the total volume of the meter
    zero (no pressure drop allowed)
    30s
  • Q8
    The meter regulator must operate at what pressure?
    19mbar (+ or – 2mbar)
    18mbar (+ or – 2mbar)
    21mbar (+ or – 2mbar)
    20mbar (+ or – 2mbar)
    30s
  • Q9
    After satisfactory testing and purging, what must be checked?
    All doors and windows are open
    Working pressure at meter
    Operation of CO detectors
    Standing pressure at the meter
    30s
  • Q10
    If pipework passes through any wall or other solid structure it must...
    take the shortest route and be sleeved
    only be steel
    pass through an existing air brick
    only be the wrapped copper
    30s
  • Q11
    When breaking into a gas supply pipe or removing a meter, what must be fitted?
    A supplementary bond
    An RCB
    A main equipotential bond
    A temporary continuity bond
    30s
  • Q12
    The emergency control valve handle or lever, in addition to being securely attached and parallel to the pipe when open, must also...
    turn the gas off when moved upwards
    turn the gas off when moved downwards
    be sealed against unauthorised use
    turn the gas off when rotated two full turns anti-clockwise
    30s
  • Q13
    Adventitious ventilation is...
    the amount of air required to burn one cubic foot of gas
    the allowance made for background air seeping into rooms
    provided to prevent the build up of radon gas
    always sited adjacent to the appliance
    30s
  • Q14
    The ventilation required for an appliance must be provided through grilles/vents with...
    a vent of at least 35cm²
    holes of less than 5mm
    both high and low level openings, 300mm apart
    openings of greater than 5mm and less than 10mm
    30s
  • Q15
    The correct amount of ventilation direct from outside, required for an open flued appliance with a heat input of 27kW (net), situated in a room is...
    121.5cm2
    100cm2
    135cm2
    90cm2
    30s

Teachers give this quiz to your class