Duct Static Pressure
Quiz by Robert Birdwell
Feel free to use or edit a copy
includes Teacher and Student dashboards
Measure skillsfrom any curriculum
Measure skills
from any curriculum
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
With a free account, teachers can
- edit the questions
- save a copy for later
- start a class game
- automatically assign follow-up activities based on students’ scores
- assign as homework
- share a link with colleagues
- print as a bubble sheet
10 questions
Show answers
- Q1Where should static pressure readings be taken in a furnace system with added accessories like coils or filters?in the middle of the duct systemby the outdoor unitbetween the furnace and any accessory that is added to that furnaceat the top of the unit30s
- Q2In a duct system, where should the airflow be transitioning to for optimal design?diagonally across the indoor unitto the front and back of the indoor unitin a circular pattern within the unitto the left and right, never the front and back of the indoor unit30s
- Q3What is the typical range of static pressure indicated by the color-coding in a duct system?4 in of water to 6 in of water2 in of water to 4 in of waterless than 2 in of water to close to 7 in of water0.5 in of water to 2 in of water30s
- Q4Where should pressure readings be taken when evaluating the supply in a furnace system?between the furnace and the coilinside the duct systemby the outdoor unitat the top of the unit30s
- Q5How should static pressure be evaluated after the installation of a furnace?use a computer programdrill holes along the mounting rail below the coil drain pan to evaluate staticestimate based on the unit's sizemeasure from a distance30s
- Q6What does the monometer reading of '0 in of watercolumn' indicate in the example provided?clogged filterlow airflowhigh static pressureno static restriction in the duct system30s
- Q7How can changes to motor airflow influence the static and velocity pressures in the duct system?changes will not affect airflowchanges are purely cosmeticchanges only affect the temperaturechanges to motor airflow can influence the total external static and airflow30s
- Q8In the provided example, what motor torque tap change would be needed for a 4-ton outdoor unit to achieve just over 1,600 CFM airflow?tap atap dtap btap c30s
- Q9What are airflow performance tables based on in HVAC systems?the color of the unitwhat did that manufacturer ship in the boxthe outdoor temperaturethe size of the duct system30s
- Q10What is the average total static pressure in the example given after adding all the readings and dividing by three?.45 in of water.25 in of water.60 in of water.10 in of water30s