  • Q1
    Give the BS number for the current document that gives guidance on ventilation.
    BS7679
    BS7671
    BS5440
    GSIUR
    30s
  • Q2
    What is the minimum size aperture allowed for a ventilation grill
    5 - 10mm
    10 - 15mm
    1- 25mm
    3 - 12mm
    30s
  • Q3
    Where an appliance is fitted into a room, a fixed allowance for adventitious openings of 35cm2 can safely be made for
    Open flued and flueless appliances
    Open flued appliances whose input is above 21kW
    Flueless appliances
    Open flued appliances
    30s
  • Q4
    If an existing air vent meets the standards and has 24 holes 5mm by 8mm its effective free area will be
    9.6cm2
    960cm2
    960,000mm2
    96cm2
    30s
  • Q5
    List the four main parts of a conventional flue
    Primary flue, heat exchanger, secondary flue, terminal
    Burner, heat exchanger, fan, terminal
    Primary flue, fan, secondary flue, terminal
    Primary flue, draught diverter, secondary flue, terminal
    30s
  • Q6
    What must be provided where a flue pipe passes through a ceiling or floor
    15mm air gap
    25mm air gap
    no air gap
    150mm air gap
    30s
  • Q7
    Where 3 or more air vents are fitted in series the intermediate vents shall be increased by .....% of the calculated air requirement
    50
    25
    10
    100
    30s
  • Q8
    Compartment ventilation is only required for open flued appliance
    False
    True
    Doesn't matter
    30s
  • Q9
    Ventilation air for combustion can be taken from a bathroom
    true
    false
    30s
  • Q10
    All ventilators should be sleeved when fitted through a cavity wall
    false
    true
    30s
  • Q11
    Ventilation grills with built in fly screen can be used with gas appliances provided they are cleaned annually
    true
    false
    30s
  • Q12
    Two DFE’s fitted in a through room would normally require 200cm2 of ventilation
    false
    true
    30s
  • Q13
    All calculations for ventilation are based on net kW. How is a rating converted that is given in gross kW
    divide by 1.11
    times by 5
    times by 1.11
    divide by 5
    30s
  • Q14
    Incomplete combustion from the burner of which type of appliance will cause an immediate danger
    open flued
    room sealed
    flueless
    30s
  • Q15
    A build up of dust around the injector of a gas burner is likely to cause
    smell of burning
    incomplete combustion
    overheating
    hotter flames
    30s