Gas Flue Systems and Ventilation
Quiz by Alan Moth
Feel free to use or edit a copy
includes Teacher and Student dashboards
Measure skillsfrom any curriculum
Measure skills
from any curriculum
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
With a free account, teachers can
- edit the questions
- save a copy for later
- start a class game
- automatically assign follow-up activities based on students’ scores
- assign as homework
- share a link with colleagues
- print as a bubble sheet
20 questions
Show answers
- Q1Give the BS number for the current document that gives guidance on ventilation.BS7679BS7671BS5440GSIUR30s
- Q2What is the minimum size aperture allowed for a ventilation grill5 - 10mm10 - 15mm1- 25mm3 - 12mm30s
- Q3Where an appliance is fitted into a room, a fixed allowance for adventitious openings of 35cm2 can safely be made forOpen flued and flueless appliancesOpen flued appliances whose input is above 21kWFlueless appliancesOpen flued appliances30s
- Q4If an existing air vent meets the standards and has 24 holes 5mm by 8mm its effective free area will be9.6cm2960cm2960,000mm296cm230s
- Q5List the four main parts of a conventional fluePrimary flue, heat exchanger, secondary flue, terminalBurner, heat exchanger, fan, terminalPrimary flue, fan, secondary flue, terminalPrimary flue, draught diverter, secondary flue, terminal30s
- Q6What must be provided where a flue pipe passes through a ceiling or floor15mm air gap25mm air gapno air gap150mm air gap30s
- Q7Where 3 or more air vents are fitted in series the intermediate vents shall be increased by .....% of the calculated air requirement50251010030s
- Q8Compartment ventilation is only required for open flued applianceFalseTrueDoesn't matter30s
- Q9Ventilation air for combustion can be taken from a bathroomtruefalse30s
- Q10All ventilators should be sleeved when fitted through a cavity wallfalsetrue30s
- Q11Ventilation grills with built in fly screen can be used with gas appliances provided they are cleaned annuallytruefalse30s
- Q12Two DFE’s fitted in a through room would normally require 200cm2 of ventilationfalsetrue30s
- Q13All calculations for ventilation are based on net kW. How is a rating converted that is given in gross kWdivide by 1.11times by 5times by 1.11divide by 530s
- Q14Incomplete combustion from the burner of which type of appliance will cause an immediate dangeropen fluedroom sealedflueless30s
- Q15A build up of dust around the injector of a gas burner is likely to causesmell of burningincomplete combustionoverheatinghotter flames30s