
IRO, PER
Quiz by Nghiep Hy
Feel free to use or edit a copy
includes Teacher and Student dashboards
Measure skillsfrom any curriculum
Measure skills
from any curriculum
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
With a free account, teachers can
- edit the questions
- save a copy for later
- start a class game
- automatically assign follow-up activities based on students’ scores
- assign as homework
- share a link with colleagues
- print as a bubble sheet
10 questions
Show answers
- Q11. In instances where there is a difference in derived limits, the Transmission Operators, Balancing Authorities, Generator Operators, Transmission Service Providers, Load-Serving Entities, and Purchasing-Selling Entities shall always operate the Bulk Electric System to which of the following?Most limiting parameterEmergency RatingNormal Continuous RatingDifference of the derived limits60s
- Q22. Each Reliability Coordinator that receives a request to implement congestion management actions shall, within what timeframe of receiving the request, implement the congestion management actions requested by the issuing Reliability Coordinator?30 minutes15 minutes60 minutes45 minutes60s
- Q33. Each Reliability Coordinator shall perform a Real-Time Assessment within what timeframe to determine if its Wide Area is exceeding any IROLs or is expected to exceed any IROLsTwice every 30 minutesOnce an hourOnce every 30 minutesTwice every three hours60s
- Q44. Reliability Coordinators must have the authority, plans, and agreements in place to immediately direct reliability entities within their Reliability Coordinator Areas to mitigate critical conditions to return the system to a reliable state. This includes taking which of the following actions?Increase thermal ratings/limits on equipmentIncrease thermal ratings/Reducing loadReadministering the markets/ Reducing loadReconfiguring the transmission system/ Reducing load60s
- Q55. Which entity shall have clear decision-making authority to act and to direct actions to be taken in order to preserve the integrity and reliability of the Bulk Electric SystemTransmission OperatorTransmission Service ProviderReliability CoordinatorGeneration Operator60s
- Q66. Whenever non-NERC certified personnel are performing any reliability-related tasks of a real-time operating position, which entity has ultimate responsibility for the performance of the reliability related tasks?Shift ManagerReliability CoordinatorOperating CompanyNERC Certified System Operator at the operating position60s
- Q77. At least every 12 months each Reliability Coordinator, Balancing Authority and Transmission Operator shall provide each of its System Operators with at least how many hours of emergency operations training?8 hours32 hours45 hours16 hours60s
- Q88. Each Transmission Operator shall staff its Real-time operating positions performing Transmission Operator reliability-related tasks with System Operators who have demonstrated minimum competency in which of the areas listed below?Resource and demand balancing/ Interchange scheduling and coordinationVoltage and reactive/ Protection and control60s
- Q99. PER-005 requires updating of the operator training plan how often?MonthlyWeeklyDailyAnnually60s
- Q1010. After an addition or modification to a task, how long do entities have to complete task-verification on the changed task?12 months from change to the task3 months from change to the task6 months from change to the task24 months from change to the task60s