22 questions
Show answers
- Q1What is the item shown in the image?ManometerWeir cupDrain scraperRodding eye30s
- Q2What is the item shown in the image?ManometerHollow shaft drain plugDrain scraperRodding eye30s
- Q3Once a blockage has been removed, what is the next course of action?Balance the systemTake air samplesTake flow samplesFlush the pipework30s
- Q4What is the item shown in the image?Gulley grabForce cupDrain augerDrain rods30s
- Q5What is the item shown in the image?Drain rodsHand spinnerGulley grabForce cup30s
- Q6Which one of the following identifies the blockage clearing tool shown in the image?Gulley grabDrain rodsWeir cupForce cup30s
- Q7What is the item shown in the image?Force cupDrain flusherDrain augerDrain scraper30s
- Q8When air testing sanitary pipework, the traps to the sanitary appliances should be sealed using which of the following methods?Filling with waterTesting bagsMasking tapeFilling with soluble foam30s
- Q9Which one of the following soundness tests is usually carried out on uPVC sanitation pipework and fittings?AirSmokeHydraulicWater30s
- Q10On how many occasions should a performance test on traps be undertaken during the commissioning process?523130s
- Q11Which one of the following states the minimum depth of seal that should be retained after a performance test has been carried out?35mm50mm25mm40mm30s
- Q12What is the item shown in the image?Air barometerAir hygrometerInflatable stopperMulti-meter30s
- Q13If you realise that a customer’s WC is connected to the surface water drain, what should you do?Advise the customer never to use the WCNothingAdvise the customer that it requires connecting to the foul water drainAdvise the customer that the WC pan needs to be changed30s
- Q14According to Building Regulations, what is the permissible drop in pressure during a soundness test on a soil stack?Nil15mm25mm10mm30s
- Q15What is the tool shown?Spade wood bitAdjustable pipe cutterCore drillHole saw30s