placeholder image to represent content

Practice Quiz 2

Quiz by Dr. Kathie Blanco

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
20 questions
Show answers
  • Q1
    How many 12 AWG conductors are allowed in an 12.5 in3 round octagonal outlet box?
    7
    2
    6
    5
    30s
  • Q2
    If the diameter of the branch conductor is doubled, the resistance of conductor …….
    increases
    decreases
    doubles
    remains unchanged
    30s
  • Q3
    What is the total voltage drop in a 12 AWG conductor that supply a 18 ampere load which is located 50 feet from the power source? The resistance of conductor is 2 ohm/1000 feet.
    3.6 volts
    18 volts
    36 volts
    1.8 volts
    30s
  • Q4
    The snap switches equipped in the panel boards are rated at 25 amperes, these switches must be protected not in excess of ……………………..
    200
    120
    150
    30
    30s
  • Q5
    What is the minimum percentage rated voltage that a storage battery should supply the emergency load?
    82 1/2 %
    80 %
    87 1/2%
    85 %
    30s
  • Q6
    What is the minimum size THWN branch circuit conductor required for a 20 HP, 480-volt, 3 Phase Induction type squirrel cage motor with nameplate FLI of 26.5 amps?
    6 AWG
    12 AWG
    10 AWG
    8 AWG
    30s
  • Q7
    A 8 AWG conductor is suitable to use at maximum ………… KW supplied with a 120 volts power source.
    30
    6000
    300
    6
    30s
  • Q8
    What is the maximum standard over current device rating used to protect instrument circuits located in a panel board?
    30 amperes
    150 amperes
    200 amperes
    15 amperes
    30s
  • Q9
    The maximum voltage rating of plug fuse is ………….. volts
    120
    36
    240
    420
    30s
  • Q10
    What is the maximum allowable ampacity of a NO.6 AWG copper type THW conductor at an ambient temperature of 75 oC?
    100 amperes
    65 amperes
    50 amperes
    85 amperes
    30s
  • Q11
    The transformer output power is 136 VA, what is transformer input power if the transformer efficiency is 85%?
    144 VA
    160 VA
    115 VA
    136 VA
    30s
  • Q12
    If the resistance of two 12 AWG conductors of 175 feet is 0.4 ohms (0.2 ohms each). What is the power loss in a conductor when the current flow of conductor is 18 amperes?
    550 watts
    488 watts
    129.6 watts
    810 watts
    30s
  • Q13
    EMT shall be securely fastened in place at least every …………..
    8 ft
    10 ft
    15 ft
    5 ft
    30s
  • Q14
    What is the current flow of a 3 kW heat strip connected to 120 volts ac power supply?
    25 amperes
    2.5 amperes
    4 amperes
    40 amperes
    30s
  • Q15
    Pipe electrodes shall have resistance to ground not to exceed …………. ohms when used alone.
    10
    35
    5
    25
    30s

Teachers give this quiz to your class