- Q1Which gauge glass contains no liquid?130s
- Q2Which gauge glass contains liquid and gas?230s
- Q3how many level gauge glasses are in the figure330s
- Q4Which gauge glass contains liquid?330s
- Q5to prove level column which valve must closed identify in the figureA and B30s
- Q6what must you do after filling a level gauge glass with solvent?allow time for the solvent to loosen dirt and sludge30s
- Q7what part represent normal operating level in the figureB30s
- Q8identify part A in the figureBlock valve30s
- Q9before a level gauge glass or level column can be flushed what action must the control man take?bypass the level switches and alarms30s
- Q10to prove sight glass which valve must closed identify in the figureC and D30s
- Q11The drain and vent valves are normally _________________________.closed and plugged30s
- Q12When flushing and proving you must communicate with the _________________________.console operator30s
- Q13what must you do before filling a level gauge glass with solvent?drain and vent the LGG30s
- Q14identify part D in the figureDrain Valve30s
- Q15You must regularly ________________________ level gauge glass and columns.flush and prove30s