placeholder image to represent content

Understand mechanical central heating controls

Quiz by Ricky Fleet

Feel free to use or edit a copy

includes Teacher and Student dashboards

Measure skills
from any curriculum

Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.

With a free account, teachers can
  • edit the questions
  • save a copy for later
  • start a class game
  • view complete results in the Gradebook and Mastery Dashboards
  • automatically assign follow-up activities based on students’ scores
  • assign as homework
  • share a link with colleagues
  • print as a bubble sheet

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
15 questions
Show answers
  • Q1
    The boiler position can be higher than the hot water cylinder in a
    One pipe gravity system
    Fully pumped sealed system
    System with microbore heating with gravity primaries
    C plan system
    30s
    Edit
    Delete
  • Q2
    This symbol from BS 1192 indicates a central heating component. Where in a central heating system would this be found?
    Question Image
    Immediately after the circulator and before the zone valve
    On a sealed system filling loop
    Cold feed from the feed and expansion cistern
    The primary flow to the hot water cylinder
    30s
    Edit
    Delete
  • Q3
    Which of the following components could be fitted with a remote sensor?
    A thermostatic radiator valve
    A diverter valve
    A kickboard convector heater
    A two port zone valve
    30s
    Edit
    Delete
  • Q4
    Which one of the following components allows the customer independent control of the hot water and central heating system?
    Cylinder thermostat
    Programmer
    Room thermostat
    Three port mid position valve
    30s
    Edit
    Delete
  • Q5
    Which of the following assists in the removal of flux from central heating pipework?
    Setting the working temperature of the system to a maximum of 650C
    Flushing the system out prior to the handover
    Adding an inhibitor to the system after commissioning
    Setting the circulator to maximum for 1 hour after soundness testing
    30s
    Edit
    Delete
  • Q6
    The steps to take prior to temporarily decommissioning a central heating system, so that an additional radiator can be installed, would include
    Switch off programmer so there is no call for heat, then drain down
    Apply temporary continuity bonding to system, then drain down
    Check for safe isolation of central heating system, then drain down
    Bung F&E and apply temporary continuity bonding to flow and return pipework
    30s
    Edit
    Delete
  • Q7
    The customer complains that the downstairs radiators are cold and the upstairs radiators are only lukewarm. This is likely to be caused by a faulty
    Three port mid position valve
    Boiler
    Room thermostat
    Circulator
    30s
    Edit
    Delete
  • Q8
    What would be the main effect on the central heating system if the circulator was installed in the position shown in this diagram?
    Question Image
    The system would be under negative pressure
    The neutral position would be at the base of the open vent
    The system would be pumping over the open vent
    The system would be mostly under negative pressure
    30s
    Edit
    Delete
  • Q9
    What would be the main effect on the central heating system if the circulator was installed in the position shown in this diagram?
    Question Image
    This is the correct arrangement of the circulator
    The neutral position would be at the base of the open vent
    System under positive pressure and pumping over the open vent
    The system would be under negative pressure and be pushing into the cistern
    30s
    Edit
    Delete
  • Q10
    What is the sequence to change a synchron motor?
    Disconnect cable, make a simple drawing of the wires, isolate the electrical supply, replace the motor and cable, reinstate and check for electrical safety
    Reinstate and check for electrical safety, disconnect cable, make a simple drawing of the wires, isolate the electrical supply, replace the motor and cable
    Isolate the electrical supply, make a simple drawing of the wires, disconnect cable, replace the motor and cable, reinstate and check for electrical safety
    Replace the motor and cable, disconnect cable, reinstate and check for electrical safety, isolate the electrical supply, make a simple drawing of the wires
    30s
    Edit
    Delete
  • Q11
    What is the purpose of the mid position diverter valve?
    To fill the heating system via the feed and expansion cistern
    To feed both the cylinder and heating circuits simultaneously
    To divert the mid position sensor
    To feed either the cylinder or heating circuit
    30s
    Edit
    Delete
  • Q12
    What is the purpose of the arrowed component?
    Question Image
    To heat the secondary water up
    To control the flow of heated water to the heating circuit
    To control the flow of heated water to the cylinder
    To heat the primary water up
    30s
    Edit
    Delete
  • Q13
    Why is it important that the pump be fitted in the correct position?
    So that the water circulates in the right direction
    To prevent cross contamination with the secondary water
    To prevent corrosion by aeration of the water
    To prevent leaks from the overflow pipe
    30s
    Edit
    Delete
  • Q14
    What is the correct position for the automatic bypass valve?
    Question Image
    A
    C
    B
    30s
    Edit
    Delete
  • Q15
    Where should the automatic bypass be fitted on a heating system?
    Question Image
    On the return from the heating to the return from the cylinder before the zone valve
    On the flow after the pump before the zone valve and into the return
    On the flow pipe from the boiler to the cold feed pipe before the pump
    On the return pipe after the zone valve from the open safety vent on the flow
    30s
    Edit
    Delete

Teachers give this quiz to your class