Understand the installation requirements of domestic hot water plumbing systems

Quiz by Ricky Fleet

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
26 questions
Show answers
  • Q1
    A rigid pipework hot water system has a working pressure of 4bar. At what pressure should the pipework be tested for soundness?
    1bar for 60 minutes
    4bar for 30mins then 6bar for 15 minutes
    6bar for one hour
    1½ times the working pressure for 15 minutes
    30s
  • Q2
    In a customer’s property, the CWSC supplies both the hot and cold water systems. The minimum size of this cistern is:
    100 litres
    Equal to 48 hour's worth of water
    230 litres
    Twice the size of the domestic hot water cylinder
    30s
  • Q3
    Which of the following appliances is most likely to offer the customer low pressure at a hot water outlet?
    Indirect cylinder
    Combination boiler
    Combination unit
    Direct cylinder
    30s
  • Q4
    If hard water is allowed to be heated above 65 degrees Celcius, what could be the consequence in the system?
    The pressure relief valve would open
    The blending valve would fail to work
    The efficiency could be affected by limescale
    Legionella could grow
    30s
  • Q5
    To overcome a dead leg for a hot water draw-off point, what course of action could be taken?
    Install a more powerful circulator
    Increase the temperature on the cylinder thermostat
    Install secondary circulation
    Increase the size of the hot water cylinder
    30s
  • Q6
    What is used at a basin outlet to prevent contamination of the water system?
    AUK2 air gap
    AUK3 air gap
    AUK4 air gap
    AG air gap
    30s
  • Q7
    What is the primary function of the open vent on a domestic hot water system?
    To balance the feed from the CWSC
    Allow hot water to be distributed at a controlled pressure
    Safety relief pipe
    Take up a hydraulic shunt
    30s
  • Q8
    To prevent the risk of legionella forming in a dead leg it should be
    No longer than 2.5 meters, as stated in BSEN806
    As short as possible
    Disinfected annually under a PPM program
    Always heated to above 50 degrees C
    30s
  • Q9
    Identify one advantage of a stored hot water system in a domestic property
    It is suitable for low water pressure areas
    It is cheaper and easier to install
    It does not require a secondary source of heat
    There is a continual supply of hot water
    30s
  • Q10
    What pipe is installed for expansion safety reasons on an open vented system?
    Closed safety vent
    Hot distribution pipe
    Cold feed
    Open safety vent
    30s
  • Q11
    Where should the hot water draw off be taken from an open vented cylinder?
    The top of the cylinder
    The side of the cylinder
    The bottom 1/3 of the cylinder
    Underneath the cylinder
    30s
  • Q12
    Part L of the Building Regulations state that insulation must be fitted to the pipework connecting a cylinder to a minimum measurement of?
    0.5m
    3m
    2m
    1m
    30s
  • Q13
    When installing the pipework to secondary circulation, where should it be connected into the cylinder?
    The bottom half of the cylinder
    The bottom 1/3 of the cylinder
    The top of the cylinder
    The top 1/3 of the cylinder
    30s
  • Q14
    What is the layering of water within hot water cylinders called?
    Simplification
    Sanitation
    Stratification
    Sterilization
    30s
  • Q15
    We install hot pipework above cold pipework for a specific reason, what is this?
    To prevent galvanic corrosion
    To prevent heat loss
    To prevent heat gain
    To prevent leaks
    30s