
1st Summative Test in TVL-12-EIM (Electrical Installation and Maintenance)
Quiz by BOBBY GREGORIO
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
This can be solid or stranded used for wiring lighting fixtures and as terminal wires.
These are bare wires used for overhead transmission lines and for ground wires
This multi-conductor cable generally used for interior wiring installation in dry and wet locations.
A wire commonly used for wiring motorized engines and appliances with high temperature, and for switchboard wiring.
A wire used for wiring electric ranges, hot water heaters, stoves and hairdryers where both heat and moisture resistance is desirable.
What is the safety device which automatically cuts off current that exceeds the circuit rating?
This wire or cable has 2, 3, or 4 conductors, stranded and used for portable cords in electrical equipment.
This is the maximum operating temperature of a THHN wire.
This wire cannot be used in wet locations.
What is the equivalent diameter size of number 8 AWG wire in millimeter (mm)?
What is the equivalent diameter size of number10 AWG wire in millimeter (mm)?
This is a multi-conductor cable generally used for interior wiring installations in dry and wet locations.
A wire commonly used for wiring motorized engines and appliances with high temperature, and for switchboard wiring.
This is a flame retardant, moisture resistant wire used for building wiring installation in dry or wet locations.
This is usually bare solid or stranded conductor used for overhead transmission lines and ground wires.
It is of electrical wiring plan that contain the name and address of the owner, signature and dry seal of master electrician or electrical engineer.
It is of electrical wiring plan that consists of type of service, single phase 2-wire or 3-wire and voltage.
It is a part of the electrical wiring plan which shows the number of branch of electrical circuit.
It is a technical representation of an electrical system proposed to be installed in building or house.
It is a part of wiring plan which shows the number of branch of electrical circuit.
It shows the classification of service, type of wiring method to be used and supplies and materials to be used by the contractor.
It is a plan of a room or floor of a building drawn to scale as if viewed from above.
The minimum circuit load of___ amperes circuit breaker shall be used for light circuit.
The minimum circuit load of___ amperes circuit breaker shall be used for convenience outlet.
Its indicate some precautionary measures against potential hazardous situation which, if not avoided, may result to minor or moderate injury.
Its indicates that a person should observe extra awareness
Its specifies hazardous situation which, if not avoided, will result to a serious injury or even death
Its means that any activity is not allowed as stated by the symbol.
Specifies a potentially hazardous situation which, if not avoided, could result to serious injury or even death.
It is the area of the house where the chandelier is usually installed.
A type of Flexible Armored Cable which conductors inside are insulated with rubber insulation.
It has varnish cambric insulation.
It has a rubber and lead sheath between the conductor and the armored
The conductors inside are insulated with thermoplastic insulation.
The appropriate tool used in cutting flexible armored cable.
It is the support used to hold the non-metallic sheathed cable in place.
It is a type of non-metallic sheathed cable that can only be used in dry and indoor applications.
It is the required short circuit protection rating for a No. 10 AWG(5.5 mm2) non-metallic sheathed cable.
It is a type of non-metallic sheathed cable that can be used in dry, moist, and corrosive environments.
It is the required short circuit protection rating for a No. 12 AWG(3.5 mm2) non-metallic sheathed cable.
It is any associated material for connecting end of stock securely.
It is used for mounting a convenience outlet on walls.
It is used for splitting conductors and splices.
It is a bend used to adopt the conduit from the surface to a particular box or fittings.
It is a process of removing sharp edges or burrs left after cutting the pipe.
What is the tool used to bend a metallic conduit?
What type of conduit is designed to lessen or eliminate fire hazard and electrical accident?
What type of fitting is used to secure EMT to metallic boxes?
What is the type of bend that makes one quarter turn?
It is a type of fitting which is used to change direction.