Understand the requirements of drainage systems

Quiz by Ricky Fleet

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
32 questions
Show answers
  • Q1
    The statutory requirements for the performance of a foul water drainage system are detailed in which one of the following?
    Water regulations
    Building regulations
    Construction regulations
    British Standard 8000
    30s
  • Q2
    Which of the following deals with gravity drainage systems inside buildings?
    BS EN 12056
    BS 6700
    BS EN 806
    Building regulation part L
    30s
  • Q3
    What building regulation document deals with drainage and waste disposal?
    Part F
    Part P
    Part H
    Part L
    30s
  • Q4
    What type of sanitary pipework system is shown in the diagram?
    Question Image
    Primary ventilated stack system
    Ventilated branch discharge system
    Modified one pipe system
    Secondary ventilated stack system
    30s
  • Q5
    What type of sanitary pipework system is shown in the diagram?
    Question Image
    Modified one pipe system
    Stub stack system
    Secondary ventilated stack system
    Primary ventilated stack system
    30s
  • Q6
    What type of sanitary pipework system is shown in the diagram?
    Question Image
    Primary ventilated stack system
    Stub stack system
    Ventilated branch discharge system
    Secondary ventilated stack system
    30s
  • Q7
    What type of sanitary pipework system is shown in the diagram?
    Question Image
    Modified one pipe system
    Ventilated branch discharge system
    Secondary ventilated stack system
    Stub stack system
    30s
  • Q8
    What type of sanitary pipework system is shown in the diagram?
    Question Image
    Stub stack system
    Primary ventilated discharge stack
    Rain water harvesting system
    Grey water harvesting system
    30s
  • Q9
    Refer to the diagram shown. What is the minimum recommended dimension shown as X between the lowest branch connection and the invert of the drain to a 'two' storey property?
    Question Image
    450mm
    350mm
    600mm
    150mm
    30s
  • Q10
    Refer to the diagram shown. What is the minimum recommended dimension shown as X between the lowest branch connection and the invert of the drain to a 'four' storey property?
    Question Image
    750mm
    450mm
    300mm
    600mm
    30s
  • Q11
    Which one of the following criteria must be observed when installing a stub stack system of sanitation pipework?
    Drain invert and ground floor level must not exceed 600 mm
    Drain invert and ground floor level must not exceed 1.8 m
    Drain invert and ground floor level must not exceed 1.3 m
    Drain invert and ground floor level must not exceed 900 mm
    30s
  • Q12
    Which one of the following criteria must be observed when installing a stub stack system of sanitation pipework?
    The highest waste connection allowed is 2.5 m above the invert of the drain
    The highest waste connection allowed is 1 m above the invert of the drain
    The highest waste connection allowed is 2 m above the invert of the drain
    The highest waste connection allowed is 1.5 m above the invert of the drain
    30s
  • Q13
    Which one of the following fittings should be used at the termination of a soil and vent pipe?
    Straight coupling
    Stand off pipe fastening
    Guarded bend
    Wire or plastic mesh cage
    30s
  • Q14
    Work is required on a below ground drainage system which has a primary ventilated stack system connected to it. Which of the following must be taken out of service during drainage operations?
    All sanitary fittings
    All WCs
    Bath only
    Wash basin only
    30s
  • Q15
    Which one of the following do sanitary appliances reduce?
    Water consumption
    Health
    Disease
    Cleanliness
    30s