Understand the requirements of drainage systems
Quiz by Ricky Fleet
Feel free to use or edit a copy
includes Teacher and Student dashboards
Measure skillsfrom any curriculum
Measure skills
from any curriculum
Tag the questions with any skills you have. Your dashboard will track each student's mastery of each skill.
With a free account, teachers can
- edit the questions
- save a copy for later
- start a class game
- automatically assign follow-up activities based on students’ scores
- assign as homework
- share a link with colleagues
- print as a bubble sheet
32 questions
Show answers
- Q1The statutory requirements for the performance of a foul water drainage system are detailed in which one of the following?Water regulationsBuilding regulationsConstruction regulationsBritish Standard 800030s
- Q2Which of the following deals with gravity drainage systems inside buildings?BS EN 12056BS 6700BS EN 806Building regulation part L30s
- Q3What building regulation document deals with drainage and waste disposal?Part FPart PPart HPart L30s
- Q4What type of sanitary pipework system is shown in the diagram?Primary ventilated stack systemVentilated branch discharge systemModified one pipe systemSecondary ventilated stack system30s
- Q5What type of sanitary pipework system is shown in the diagram?Modified one pipe systemStub stack systemSecondary ventilated stack systemPrimary ventilated stack system30s
- Q6What type of sanitary pipework system is shown in the diagram?Primary ventilated stack systemStub stack systemVentilated branch discharge systemSecondary ventilated stack system30s
- Q7What type of sanitary pipework system is shown in the diagram?Modified one pipe systemVentilated branch discharge systemSecondary ventilated stack systemStub stack system30s
- Q8What type of sanitary pipework system is shown in the diagram?Stub stack systemPrimary ventilated discharge stackRain water harvesting systemGrey water harvesting system30s
- Q9Refer to the diagram shown. What is the minimum recommended dimension shown as X between the lowest branch connection and the invert of the drain to a 'two' storey property?450mm350mm600mm150mm30s
- Q10Refer to the diagram shown. What is the minimum recommended dimension shown as X between the lowest branch connection and the invert of the drain to a 'four' storey property?750mm450mm300mm600mm30s
- Q11Which one of the following criteria must be observed when installing a stub stack system of sanitation pipework?Drain invert and ground floor level must not exceed 600 mmDrain invert and ground floor level must not exceed 1.8 mDrain invert and ground floor level must not exceed 1.3 mDrain invert and ground floor level must not exceed 900 mm30s
- Q12Which one of the following criteria must be observed when installing a stub stack system of sanitation pipework?The highest waste connection allowed is 2.5 m above the invert of the drainThe highest waste connection allowed is 1 m above the invert of the drainThe highest waste connection allowed is 2 m above the invert of the drainThe highest waste connection allowed is 1.5 m above the invert of the drain30s
- Q13Which one of the following fittings should be used at the termination of a soil and vent pipe?Straight couplingStand off pipe fasteningGuarded bendWire or plastic mesh cage30s
- Q14Work is required on a below ground drainage system which has a primary ventilated stack system connected to it. Which of the following must be taken out of service during drainage operations?All sanitary fittingsAll WCsBath onlyWash basin only30s
- Q15Which one of the following do sanitary appliances reduce?Water consumptionHealthDiseaseCleanliness30s