placeholder image to represent content

Understand the requirements of the cold water supplies into domestic dwellings

Quiz by Ricky Fleet

Our brand new solo games combine with your quiz, on the same screen

Correct quiz answers unlock more play!

New Quizalize solo game modes
29 questions
Show answers
  • Q1
    When installing a new water service pipe to a property, it should normally be buried between what depths?
    1350mm to 1750mm
    350mm to 750mm
    135mm to 1750mm
    750mm to 1350mm
    30s
  • Q2
    Which of the following materials is not allowed to be installed on new cold water systems?
    MDPE
    Stainless steel
    Lead
    Copper
    30s
  • Q3
    The pipe connecting the undertaker’s water main to the boundary stop valve is called
    Service main
    Communication pipe
    Distributing main
    Branch pipe
    30s
  • Q4
    Water suitable for drinking is known as?
    Wholesome water
    Rainwater
    Grey water
    Black water
    30s
  • Q5
    Wholesome water is fluid category
    3
    5
    2
    1
    30s
  • Q6
    The average water consumption for a household in the last twenty years is...
    100 litres
    50 litres
    200 litres
    150 litres
    30s
  • Q7
    The government want new sustainable housing to reduce water consumption to...
    150 litres
    80 litres
    100 litres
    50 litres
    30s
  • Q8
    Pipes below roads that deliver wholesome water to properties are called
    Supply mains
    Water mains
    Distribution mains
    Feed mains
    30s
  • Q9
    The boundary stop valve is located...
    Externally just outside the property boundary on the pavement
    Externally just within the property boundary on the driveway
    Internally, normally under the kitchen sink
    Externally in the road
    30s
  • Q10
    What is this component and what is it used for
    Question Image
    Pressure reducing valve, used on high pressure incoming mains water supply
    Brass filter, used with float operated valves
    Brass ferrule, used to connect directly into a local mains supply
    Non-return valve, used on outside taps
    30s
  • Q11
    What is the maximum height a service stop valve should be above floor level
    150mm
    200mm
    100mm
    125mm
    30s
  • Q12
    A local main is the property of...
    Water authority
    Building inspector
    Local council
    Fire authority
    30s
  • Q13
    What is the name of the pipe that connects the boundary stop vale to the service stop vavle inside a property
    Branch mains
    Service pipe
    Communication pipe
    Local mains
    30s
  • Q14
    Which statement below is CORRECT
    A water supply entering a property with air vents below a suspended floor needs to be sleeved but not insulated
    A water supply entering a property through a duct requires the ends to be sealed
    A water supply entering a property less than 750mm vertically from the external face of the building does not require insulation
    A water supply pipe entering a property less than 750mm below the ground does not require insulation
    30s
  • Q15
    Identify the component shown in the image
    Question Image
    Internal water meter box
    Boundary water meter box
    Local mains inspection box
    Groundbreaker water meter box
    30s

Teachers give this quiz to your class